Trane heat pumps recover waste heat for district heating project
Italy – A waste heat recovery project in Sauze d’Oulx, Italy, is using three Trane high-temperature heat pumps to increase the output and efficiency of an existing district heating plant.
The system recovers low-temperature heat at around 30°C and upgrades it to approximately 80°C for distribution through the heating network, with the completed project expected to deliver a return on investment in less than two years.
Meco Sauze Srl installed one Trane XStream RTWF 125 HE heat pump on each of the plant’s three cogeneration engines, which each have an electrical output of 1,334kW. Delivered in collaboration with ETS (Ecotermica Servizi SpA), the project is now fully commissioned and operational.
The installation is designed to increase heating capacity, improve overall plant efficiency and reduce carbon emissions by making use of thermal energy that was previously too low in temperature to be supplied directly to the district heating network.
Upgrading low-temperature heat
The Sauze d’Oulx plant was already producing both electricity and useful heat through cogeneration, but part of the thermal energy available from the intercooler could not be fully utilised because of its relatively low temperature.
The RTWF heat pumps recover this energy at approximately 30°C and raise it to around 80°C, which Meco Sauze identifies as the minimum usable temperature for distribution through its district heating system.
As the heat pumps are integrated with the cogeneration plant, they can also be powered using electricity generated on site.
For Meco Sauze, the objective was to improve the efficiency and sustainability of the existing plant without compromising the reliability required for district heating operation. The project was the company’s first installation of this type, making both proven technology and application support important considerations.
Projects like Sauze d’Oulx show how heat pump technology can unlock additional value from existing cogeneration infrastructure, supporting both decarbonisation goals and long-term asset value.
Fabio Ritucci, Equipment Sales Area Manager at Trane
Site-specific integration
Trane was selected for its high-temperature screw heat pump technology and its ability to work with ETS and Meco Sauze on a system designed around the site’s operating conditions.
Gianluca Giustetto of ETS said the project depended on developing a solution specifically for the existing plant rather than applying an off-the-shelf approach.
“By working closely with Trane and Meco Sauze, we were able to develop a solution that could be integrated effectively into the existing district heating system and turn a technical opportunity into a practical improvement for the network,” he said.
Strengthening the district heating network
Meco Sauze said the project forms part of the continued development of its district heating system by allowing the plant to make greater use of energy that had previously been more difficult to utilise.
Maurizio Cassano of Meco Sauze said the installation strengthens the plant’s contribution to the network while supporting the company’s operational objectives and sustainability profile.
The project demonstrates how high-temperature heat pumps can be integrated with existing cogeneration equipment to recover otherwise underused low-grade heat and convert it into useful energy for district heating distribution.