Panasonic adds R32 heat recovery VRF to ECOi EX
UK – Panasonic Heating & Cooling Solutions has extended its ECOi EX VRF range with a new three‑pipe series using R32 refrigerant, targeting commercial buildings that require simultaneous heating and cooling and higher seasonal efficiencies.
The ECOi EX MF4 units are designed as compact 10HP modules, scalable up to 12HP per outdoor unit and combinable in banks of three to deliver up to 36HP, serving as many as 52 indoor units. Panasonic quotes seasonal efficiencies of ηs,c 308.3% in cooling and ηs,h 171.0% in heating, with operation from –20°C to 52°C to cover most European commercial applications.
Lower refrigerant charge and R32 safety strategy
The move to R32 is positioned to cut charge sizes and ease compliance on many projects. Panasonic states that the MF4 series uses 41% less refrigerant than comparable R410A systems, which increases the number of building designs that fall below thresholds requiring additional mitigation measures for A2L refrigerants.
Where extra safeguards are needed, the ECOi EX R32 line incorporates leak detection and alarm functions designed to meet EN 378 and IEC 60335‑2‑40. A three‑pipe heat recovery box is available with or without an integrated safety valve kit, allowing consultants and contractors to match system layout to project‑specific risk assessments and regulatory requirements.
Heat recovery VRF for multi‑zone commercial buildings
As a three‑pipe heat recovery VRF, the MF4 series is intended for offices, hotels, mixed‑use and other multi‑zone schemes where concurrent heating and cooling can significantly raise system COP and reduce carbon intensity. The broad capacity range and high maximum number of indoor connections give designers more flexibility in dense, multi‑tenant buildings, while the compact footprint is aimed at constrained plantrooms and rooftop sites.
Indoor options on the R32 VRF platform include units incorporating Panasonic’s nanoe X air treatment and energy recovery ventilation, with integration to smart building and multisite control platforms for centralised operation.
Key points
- Panasonic launches ECOi EX MF4 three‑pipe R32 VRF for simultaneous heating and cooling.
- Modular 10–12 HP units can be combined to 36 HP and up to 52 indoor units.
- Claimed seasonal efficiencies of ηs,c 308.3% (cooling) and ηs,h 171.0% (heating).
- R32 design uses 41% less refrigerant than comparable R410A systems, easing compliance on many projects.
- Integrated R32 safety measures include leak detection and alarms to EN 378 and IEC 60335‑2‑40.
- Targets offices, hotels and multi‑zone commercial buildings needing heat recovery and compact plant.