3 min read
Technician and homeowner reviewing heat pump details outside a house.

Nesta report finds faults across all 92 heat pump audits

UK – A Nesta report examining heat pump installations in Bristol has found design, installation or commissioning faults across all 92 systems included in three phases of auditing. The research, undertaken with Bristol City Council, identified widespread problems with commissioning and installation quality, while available performance data showed efficiencies below or close to expected levels.

Nesta funded the latest 39 technical audits in Bristol City Council social housing, carried out between June and November 2025. These were combined with 53 earlier audits undertaken by Bristol City Council with MCS and the University of Bristol, comprising 28 retrofit systems across social and private homes and 25 new-build social homes.

The 39 systems in the Nesta-funded phase had been installed by different contractors and averaged seven years old, with the oldest installation 17 years old. Nesta subsequently funded repair visits to 30 of the properties and carried out tenant research alongside the technical work.

Installation and commissioning problems

All 39 systems in the Nesta-funded audit had at least one fault, while problems were also identified across each of the earlier 53 audits.

Physical installation issues were found in 35 of the 39 properties in the latest phase. Inadequate external pipe insulation was the most common problem, affecting 20 systems, while other issues included system design faults and incorrect control settings.

Commissioning emerged as a particular weakness. Weather compensation was disabled in 36 of the 39 systems, meaning they were operating at fixed flow temperatures rather than adjusting according to outdoor conditions. Nesta said correctly configured weather compensation is strongly associated with improved heat pump efficiency.

Performance below expectations

Performance data was available for 15 of the 39 heat pumps in the latest audit group. These achieved an average seasonal performance factor of 2.79, with individual results ranging from 1.9 to 3.3.

Among the earlier audits, performance data from 16 retrofit systems showed an average SPF of 2.6, while the 25 new-build systems averaged 2.95.

Nesta noted that the MCS minimum design requirement is an SPF of 2.8. Using July 2026 energy prices, it calculated that a heat pump on a flat-rate electricity tariff would need an SPF of around 3.03 to match the running cost of an 85% efficient gas boiler.

Despite the number of faults identified, many did not require major system changes. Engineers returned to 30 properties to carry out remedial work including improving pipe insulation, reducing flow temperatures and enabling or adjusting weather compensation.

The average repair visit cost around £204 excluding VAT, with labour accounting for 94% of the total. Nesta said the findings suggest that many installation and commissioning problems can be corrected without replacing major equipment.

There was, however, insufficient post-remediation monitoring data to establish how much the repairs improved seasonal performance.

Tenant handover also highlighted

The research also identified weaknesses in how residents were introduced to and supported with their heat pump systems.

Nesta carried out 31 initial tenant interviews in the latest audit phase, followed by six telephone interviews after remedial work. Some residents said their homes remained consistently warm, while others reported cold rooms, slow heat-up times, hot water problems or concerns over electricity bills.

Understanding of system operation varied considerably. Some residents were unaware they had a heat pump, while others operated their systems in short bursts in a similar way to a gas boiler or switched them off completely.

Nesta said clearer handover information and continued support are particularly important in social housing, where residents may inherit a heat pump when moving into a property rather than choosing the technology themselves.

The organisation has published an accompanying action guide calling for stronger procurement requirements, better quality assurance, improved staff training and more effective tenant support as social landlords increase heat pump deployment.

Share this story by:

The stories that matter, delivered to your inbox

A concise round-up of heat pump news, policy and market developments

Trusted by heat pump professionals

  • Policy and market updates

  • Product and technology news

  • Independent industry insight

MHI Q-ton potable hot water heat pump
DiversiTech ASHP solutions
Hisense heat pumps
IOR signup
EHPA Heat Pump Forum & Awards 2026
R.A.C.E.S Society
Upcoming events