Air conditioning added to Boiler Upgrade Scheme
UK – Air conditioning technology in residential properties is now covered by the Boiler Upgrade Scheme (BUS) in England and Wales, although some in the industry believe its inclusion results in more questions than answers.
Legislation has come into force which means that air-to-air heat pumps, to use the modern parlance, will be eligible for funding of £2,500 under the Government scheme once the technology is fully implemented into the Microgeneration Certification Scheme (MCS).
The grant level is lower than the £7,500 available for air-to-water, ground source or exhaust air installations (£9,000 from this summer for air source replacing an oil or LPG system). The eligibility rules remain the same, however, meaning that any upgrade must involve compete replacement of a fossil-fuel system in a property for both space heating and hot water.
Many of the obstacles to adoption were discussed at The Heat Pump Show in Newark recently and the issue has prompted further debate across LinkedIn and other online forums.
The BUS is administered by Ofgem on behalf of DESNZ (Department for Energy Security and Net Zero), and official guidance from the energy regulator includes the following:
- The new heat pump will be sized to meet the full space heating needs of the property, whether it is installed alone or in combination with a supplementary appliance
- The new heat pump will be capable of meeting the full space heating and hot water heating needs of the property, either alone or in combination with a supplementary appliance
- Any supplementary heating system must not be fuelled by fossil fuels.
This is likely to mean that an indoor air conditioning unit is required for each habitable room, connected to an outdoor unit(s) of sufficient capacity. Also, as air conditioning systems do not typically provide integrated domestic hot water, an alternative solution would result in further costs for the homeowner.
A further potential obstacle for heating installers is that, due to the range of refrigerant gases and higher working pressures present in air conditioning compared to hydronic systems, ‘Technical Supervisors’ within an MCS business must hold competence in Refrigeration, Air Conditioning and Heat Pumps (RACHP) at Level 3 (or above). The MCS guidance states: “It’s important to note that this applies only to the Technical Supervisor role within a business, who is the individual that takes overall responsibility for the safety, technical standard and quality of every installation delivered under the redeveloped installer scheme. The Technical Supervisor may be someone already within an installation business, or installers may choose to hire or sub-contract this role for air-to-air heat pump installations, provided this is done in line with MCS requirements.’’
A list of relevant training courses is available on the MCS website.